MIL-PRF-14516G
STANDARDS
DEPARTMENT OF DEFENSE
MIL-STD-810 - Environmental Test Methods and Engineering Guidelines
(Unless otherwise indicated, copies of the above standard are available from the
Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA
19111-5094)
3. REQUIREMENTS
3.1 First article. When specified (see 6.2), a sample shall be subjected to a first article
inspection in accordance with 4.1.1.
3.2 Conformance. A sample shall be subjected to conformance inspection in accordance
with 4.1.2.
3.3 Operating requirements. The heaters shall satisfy the following user-oriented
requirements.
3.3.1 Operation. The heater shall operate with all specified fuels and under all specified
conditions herein with no electrical power.
3.3.2 Ignition. The heaters shall not require any electrical power for ignition. Ignition shall
be accomplished safely in ten minutes or less.
3.3.3 Monitoring. The heaters shall incorporate a means for viewing the entire combustion
flame during operation.
3.3.4 Liquid fuel. The heaters shall be safely operated with all of the fuels listed in Table I.
TABLE I. Compatible Fuels
Military Symbol Ambient Temperature
Range (8F)
DF-2
above 25 8F
DF1
above 10 8F
DFA
above 60 8F
JP8
above 60 8F
2